Burning test machine problem solving method

There are many problems in the burning test opportunities in daily operations. The following are common ones, and then the exclusion methods are given separately. I hope everyone can learn from them:

  1. After the computer software is online, the message box appears to be overloaded. Burning test machine problem solving method


Method of exclusion:

Check if the communication line between the computer and the test machine is off; check if the online selection sensor is selected correctly; check if the sensor has been hit during the most recent test or keyboard operation; check whether the software calibration or calibration function is used before the problem occurs; check whether it is manual Changed the calibration value, calibration value, or other information in the hardware parameters.

2. The power of the test machine host is not bright, and the device cannot move up and down. Burning test machine problem solving method


Method of exclusion:

Check whether the power line connected to the test machine is connected properly; check if the emergency stop switch is in the screwed state; check whether the power supply voltage of the test machine is normal; check whether the fuse on the machine socket is blown, please remove the spare fuse and install it. .

3. The test machine's main unit has power, and the equipment cannot move up and down.


Method of exclusion:

Check whether the equipment can not be moved after 15S, because the host needs self-test when it starts up, it takes about 15S time; check whether the upper and lower limits are at the proper position, and have a certain running space; check whether the power supply voltage of the connected test machine is normal burning test. Machine problem solving method

Combustion testing machine, glow wire testing machine, leakage tracking test machine, insertion force testing machine, microcomputer tensile testing machine


SHENHZEN BONAD INSTRUMENT CO.,LTD provide all kinds of burning test machines: Combustion testing machine, glow wire testing machine, leakage tracking test machine, insertion force testing machine, microcomputer tensile testing machine.

 

more detial ,please kindly contact me.

Email:Alice@szbonad.com

whatsapp:0086-18825130384

 
 
Home  |  Products  |  News  |  About us  |  Feedback  |  Contact us  |  
Copyright © 2008-2015 Hong Kong Bonad Technology Limited | Shenzhen Bonad Instrument Co., LTD. All Rights Reserved.
 
    Add:C505, Hongdu Building,Bao\'an45 district,Shenzhen,518101,Guangdong Province,China    Tel:+86-13380391156    Fax:0755-23721200    Email:Alice@szbonad.com